USE AND OPERATION:
These valves are used to control actuator’s movements and block in one direction in order to have a under control descent of a load; load’s weight doesn’t carry it away, as the valve prevents any cavitations of the actuator.
MATERIALS AND FEATURES:
Body: zinc-plated steel.
Internal parts: hardened and ground steel.
Seals: BUNA N standard.
Tightness: minor leakage.
Standard setting: 320 Bar.
Valve setting must be at least 1,3 times more than load pressure in order to enable the valve to close even when undergone to the maximum load pressure.
APPLICATIONS:
Connect V1 and V2 to the pressure flow, C1 to the free flow side of the actuator and C2 to the actuator’s side you want the flow to be blocked. In-line mounting.
ON REQUEST:
• other settings available
• sealing cap (CODE/P) and arranged for sealing cap (CODE/PP)
CodicePortata massimaPressione massimaPressione aperturaV-CL (mm)L1 (mm)L2 (mm)L3 (mm)L4 (mm)L5 (mm)L6 (mm)L7 (mm)H (mm)S (mm)Peso
VBCDE3/8SE353501:3,13/8"90.0162.032.048.023.042.048.058.060.030.01.19
VBCDE3/8SE/RP18353501:83/8"90.0162.032.048.023.042.048.058.060.030.01.19
VBCDE1/2SE503501:3,11/2"90.0162.035.048.023.040.548.058.060.030.01.13
VBCDE1/2SE/RP18503501:81/2"90.0162.035.048.023.040.548.058.060.030.01.13
VBCDE3/4SE1053501:3,13/4"118.0190.047.071.023.047.072.572.580.035.02.15
VBCDE3/4SE/RP181053501:83/4"118.0190.047.071.023.047.072.572.580.035.02.15
Note

QTY + -