“LG1” vertical operation level gauges series are suitable to signal the minimum or maximum level of a fluid in the tank. The fixing flange foresees three fixing typologies in only one execution. The “LG1” have the electric exchange contacts in the standard execution and simple electric contact in the execution with an incorporate thermostats. “LG1R” series is the execution with the possibility to regulate the height of the float, while the “LG1T” series includes also the electric contact for the control of the temperature.
Technical Features:
Flange of fastening : in anodized alluminuim.
Rod: in stainless steel.
Float: in nylon.
Assembly : in vertical position by 3 different types of hydraulic connection in only one execution:
- two holes flange (180°).
- three holes flange (120°).
- 1” BSP Male thread connection.
Installation: must be foreseen at least at 50mm from ferrous walls and far from magnetic fields.
Maximum inclination: 15°
Working temperature: from -10 °C to + 90°C.