Technical data:
- Return filters in tank with service cover and breather.
- By-pass valve setting150kPa (1,5 bar) per ISO 3968
- Operating temperature from -20°C to +100°C.
- Compatibility with hydraulic fluids per ISO 2943.
- Flow rate and pressure drop per ISO 3968 with oil kinematic viscosity 30cSt at 40°C and density 0,875 kg/dm3.
- Replacement element includes spring and O-ring seal.